top of page

Cellix Technical Team
Apr 18, 20242 min read
4U Pump: Simple steps to connect 4U pump to the sample reservoir and flow sensor
A precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required.
60

Cellix Technical Team
Feb 20, 20243 min read
How to get started with your Mirus Evo 8-channel Pulse-Free Microfluidic Syringe Pump and Multiflow8
patented, precision, microfluidic, 8-channel syringe pump for cell analysis under shear flow mimicking physiological flow in the human vascu
86

cellixmarketing
Feb 12, 20242 min read
A Self-Sealing Modular Microfluidic System Using PDMS Blocks with Magnetic Connections -By Ecker et al., 2023.
modular microfluidic system using magnets and casted O-ring-like structures.
131

Cellix Technical Team
Feb 7, 20242 min read
Understanding Flow Sensors: For Microfluidic Syringe and Pressure Pumps
Flow sensors for Cellix's microfluidic pumps enable active feedback, for microfluidic applications, where accurate and stable flow rate is
104


Cellix Technical Team
Jan 29, 20243 min read
Droplet generation of water-in-oil droplets using Cellix's 4U Pump: a step-by-step process
Precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required.
46

Cellix Technical Team
Jan 22, 20244 min read
rJararacin, a recombinant disintegrin from Bothrops jararaca venom: Exploring its effects on hemostasis and thrombosis - David et al., 2023.
secondary structure of jararacin and its effects on hemostasis and thrombosis | Platelet adhesion under flow | In vitro thrombogenesis
69


Cellix Technical Team
Jan 15, 20243 min read
How to conduct a Thrombosis Assay using Cellix's VenaFlux Basic setup with ExiGo pump
VenaFlux Solutions mimic human blood vessels | conduct a Thrombosis Assay | automated high-throughput flow assay system
43

Cellix Technical Team
Jan 8, 20243 min read
Automatic Design of Microfluidic Gradient Generators – By Fink et al., 2022.
Background Microfluidic concentration gradient generators are essential in research as they create spatially resolved concentration...
72

Cellix Technical Team
Nov 7, 20233 min read
Lack of transporter-like protein SLC44A2 causes hearing impairment and a rare red blood phenotype
The presence or absence of specific antigens at the red blood cell surface determines blood phenotypes.
57

Cellix Technical Team
Nov 1, 20234 min read
Answers to your questions about the VenaFlux Solutions : Frequently Asked Questions (FAQs)
VenaFlux Solutions offers a range of packages to fit different budgets, empowering researchers with innovative tools
58

Cellix Technical Team
Oct 22, 20234 min read
The rate of platelet activation determines thrombus size and structure at arterial shear
Antiplatelet therapy reduces stroke and heart attack recurrence risk, but thrombotic diseases remain a leading cause of death
86

Cellix Technical Team
Oct 16, 20234 min read
EMT status of circulating breast cancer cells and impact of fluidic shear stress – By Jin et al., 20
Tumour metastasis is a major cause of cancer death, but scientists still don’t fully understand its mechanisms.
19

cellixmarketing
Oct 9, 20233 min read
New insights into prothrombotic state of post-COVID syndrome patients
Post-COVID Syndrome (PCS) involves long-lasting, unexplained symptoms after SARS-CoV-2 infection, impacting quality of life.
23

Cellix Technical Team
Oct 2, 20233 min read
Maximising Efficiency and Performance: Using UniGo and ExiGo Pumps Together
Microfluidic syringe pump | Microfluidic Pressure Pump | Wide range of viscosities and temperatures | Handle large volumes of fluid
37

Cellix Technical Team
Sep 25, 20234 min read
Cardiovascular: Stents; Drug Eluting Stents; Platelet Adhesion
Assess the ability of xemilofiban released in conjunction with fluvastatin, to prevent thrombus formation/platelet adhesion to fibrinogen
36

Cellix Technical Team
Sep 20, 20233 min read
Chronic platelet activation contributes to Alzheimers Disease and its progression
Thrombus Formation Assay Under Physiological Flow | ExiGo pump to create physiological flow conditions ranging from 200 to 1000 sec⁻¹
18


Cellix Technical Team
Aug 14, 20232 min read
VenaFlux Solutions for Thrombosis assay : Technical Specifications
Quantify cell adhesion, rolling, migration, cell-cell adhesion, platelet aggregation, thrombi formation - all under shear flow
38

Cellix Technical Team
Jul 31, 20232 min read
Understanding Cellix's Microfluidic Hydrodynamic Focusing Set-up
Cellix's microfluidic hydrodynamic focusing set-up is a cost-effective solution for hydrodynamic focusing.
34

Cellix Technical Team
Jul 12, 20231 min read
ExiGo Manifold: maximizing the flexibility of your microfluidic setup
The ExiGo manifold is a specialised microfluidic channel selector designed to work with an ExiGo pump.
136

Cellix Technical Team
Jun 26, 20234 min read
Bacteriology: E. Coli; Adhesion; Biofilm Formation
Importance of physiological shear stress environment required for E. coli adhesion, colonisation and biofilm formation | E. coli infection
80
bottom of page