top of page

4U Pump: Simple steps to connect 4U pump to the sample reservoir and flow sensor
A precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required.
Cellix Technical Team
Apr 18, 20242 min read
65

How to get started with your Mirus Evo 8-channel Pulse-Free Microfluidic Syringe Pump and Multiflow8
patented, precision, microfluidic, 8-channel syringe pump for cell analysis under shear flow mimicking physiological flow in the human vascu
Cellix Technical Team
Feb 20, 20243 min read
92

A Self-Sealing Modular Microfluidic System Using PDMS Blocks with Magnetic Connections -By Ecker et al., 2023.
modular microfluidic system using magnets and casted O-ring-like structures.
cellixmarketing
Feb 12, 20242 min read
135

Understanding Flow Sensors: For Microfluidic Syringe and Pressure Pumps
Flow sensors for Cellix's microfluidic pumps enable active feedback, for microfluidic applications, where accurate and stable flow rate is
Cellix Technical Team
Feb 7, 20242 min read
110


Droplet generation of water-in-oil droplets using Cellix's 4U Pump: a step-by-step process
Precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required.
Cellix Technical Team
Jan 29, 20243 min read
47

rJararacin, a recombinant disintegrin from Bothrops jararaca venom: Exploring its effects on hemostasis and thrombosis - David et al., 2023.
secondary structure of jararacin and its effects on hemostasis and thrombosis | Platelet adhesion under flow | In vitro thrombogenesis
Cellix Technical Team
Jan 22, 20244 min read
70


How to conduct a Thrombosis Assay using Cellix's VenaFlux Basic setup with ExiGo pump
VenaFlux Solutions mimic human blood vessels | conduct a Thrombosis Assay | automated high-throughput flow assay system
Cellix Technical Team
Jan 15, 20243 min read
47

Automatic Design of Microfluidic Gradient Generators – By Fink et al., 2022.
Background Microfluidic concentration gradient generators are essential in research as they create spatially resolved concentration...
Cellix Technical Team
Jan 8, 20243 min read
79

Answers to your questions about the VenaFlux Solutions : Frequently Asked Questions (FAQs)
VenaFlux Solutions offers a range of packages to fit different budgets, empowering researchers with innovative tools
Cellix Technical Team
Nov 1, 20234 min read
61

The rate of platelet activation determines thrombus size and structure at arterial shear
Antiplatelet therapy reduces stroke and heart attack recurrence risk, but thrombotic diseases remain a leading cause of death
Cellix Technical Team
Oct 22, 20234 min read
86

EMT status of circulating breast cancer cells and impact of fluidic shear stress – By Jin et al., 20
Tumour metastasis is a major cause of cancer death, but scientists still don’t fully understand its mechanisms.
Cellix Technical Team
Oct 16, 20234 min read
19

New insights into prothrombotic state of post-COVID syndrome patients
Post-COVID Syndrome (PCS) involves long-lasting, unexplained symptoms after SARS-CoV-2 infection, impacting quality of life.
cellixmarketing
Oct 9, 20233 min read
23

Maximising Efficiency and Performance: Using UniGo and ExiGo Pumps Together
Microfluidic syringe pump | Microfluidic Pressure Pump | Wide range of viscosities and temperatures | Handle large volumes of fluid
Cellix Technical Team
Oct 2, 20233 min read
39

Cardiovascular: Stents; Drug Eluting Stents; Platelet Adhesion
Assess the ability of xemilofiban released in conjunction with fluvastatin, to prevent thrombus formation/platelet adhesion to fibrinogen
Cellix Technical Team
Sep 25, 20234 min read
36

Chronic platelet activation contributes to Alzheimers Disease and its progression
Thrombus Formation Assay Under Physiological Flow | ExiGo pump to create physiological flow conditions ranging from 200 to 1000 sec⁻¹
Cellix Technical Team
Sep 20, 20233 min read
19


VenaFlux Solutions for Thrombosis assay : Technical Specifications
Quantify cell adhesion, rolling, migration, cell-cell adhesion, platelet aggregation, thrombi formation - all under shear flow
Cellix Technical Team
Aug 14, 20232 min read
39

Understanding Cellix's Microfluidic Hydrodynamic Focusing Set-up
Cellix's microfluidic hydrodynamic focusing set-up is a cost-effective solution for hydrodynamic focusing.
Cellix Technical Team
Jul 31, 20232 min read
38

ExiGo Manifold: maximizing the flexibility of your microfluidic setup
The ExiGo manifold is a specialised microfluidic channel selector designed to work with an ExiGo pump.
Cellix Technical Team
Jul 12, 20231 min read
136

Bacteriology: E. Coli; Adhesion; Biofilm Formation
Importance of physiological shear stress environment required for E. coli adhesion, colonisation and biofilm formation | E. coli infection
Cellix Technical Team
Jun 26, 20234 min read
86

4U 4-channel Microfluidic Pump: Accurate and Pulse-Free Flow for Microfluidic Applications
Precision pressure pump for a variety of microfluidic applications, where accurate and stable flow rate delivery is required
Cellix Technical Team
Jun 12, 20231 min read
147