top of page

DropChip

3 Droplet generators and flow splitter on one chip

Back to top
Droplet Generation Icon.jpg
Droplet Generation_Cell Encapsulation Ic
cost effective.png
flow splitter.jpg
ic-mood.png
pulse free 1.png
pipette.png
microscope.png

DROPLET GENERATION ASSAYS with oil and water phases producing uniform, stable, mono-dispersed droplets.

DROP-SEQ (CELL & PARTICLE ENCAPSULATION) ASSAYS easily achieved with splitter and dual-injection flow focusing droplet generator.

REUSABLE & COST-EFFECTIVE: 1 x Flow splitter and 3 x Droplet Generator junctions on-chip with 2 different designs for single or dual injection of dispersed phase.

FLOW SPLITTER & FLOW FOCUSING JUNCTIONS on one single chip enabling a wide range of experimental set-ups.

PLUG & PLAY with easy-to-connect tubing with standard 25G needles, no bulky luer connectors.

COMPATIBLE WITH MICROFLUIDIC SYRINGE PUMPS & MICROFLUIDIC PRESSURE PUMPS including Cellix's ExiGo, UniGo and 4U pumps for precise pulse-free stable flow rates.

COMPATIBLE WITH STANDARD PIPETTES for easy coating of chips with reagents, e.g. to ensure channel hydrophobicity for water-in-oil droplet generation.  

COMPATIBLE WITH IMMUNOFLUORESCENCE MICROSCOPY for cell encapsulation studies.  

how-does-it-work.png

HOW DOES IT WORK?

DropChips are fabricated from plastic (acrylic) and have a footprint of 40mm x 50mm (W x L).

DropChips are available with channels pre-treated as hydrophobic or hydrophilic:

  • Hydrophobic to achieve water-in-oil droplets.

  • Hydrophilic to achieve oil-in-water droplets.

 

DropChips are available in packs of 2, 5 or 10.

Droplet generation_water-in-oil_hydropho
Droplet generation_oil-in-water_hydrophi

Hydrophobic channels:

Water-in-oil droplet generation

Hydrophilic channels:

Oil-in-water droplet generation

As illustrated in the schematic below, each DropChip contains:

  • 1 x Flow Splitter and

  • 3 x Droplet Generator junctions:

    • 2 x Flow-Focusing junctions, single-injection dispersed phase

    • 1 x Flow Focusing junction with dual-injection dispersed phase

This gives the user flexibility for experiments in flow focusing with single and dual-injection of dispersed phase.

Examples are illustrated in the images below.

Droplet Frequency

The creation of uniform, mono-dispersed  stable droplets is achieved with microfluidic syringe pumps such as Cellix's ExiGo pump or microfluidic pressure pumps such as Cellix's UniGo or 4U pumps.  Cellix's team conducted 3D scattering measurements to confirm frequency of droplets which can be achieved at defined flow rates as illustrated in the images and frequency graph below.  If you have a specific frequency you want to achieve, contact us for more help.

Droplet Frequency in DropChip  with channel dimensions 70um x 70um

Droplet Generation Frequency Graph.jpg

Droplet Size

There are a variety of different droplet sizes possible and one of the biggest influencing factors of droplet size is the geometry and size of the channel dimensions.  Cellix's team conducted 3D scattering measurements to confirm size and volume of droplets which can be achieved with the two different types of droplet generator contained in the DropChip.  Schematics for each of the droplet generators available on Cellix's Dropchip are illustrated below and the following table provides a summary of the droplet sizes (diameter and volume) which may be achieved depending on the DropChip dimensions.

Table_Droplet Sizes_DG1 and DG3.jpg
Droplet Generator 1 and 3_Flow Focusing.

Droplet Generator junction 1 & 3 (DG1 and DG3):

Flow Focusing, single injection of dispersed phase

Droplet Generator 2_Co-flow Focusing.jpg

Droplet Generator junction 2 (DG2):

Flow Focusing, dual injection of dispersed phase

Table_Droplet Sizes_DG2.jpg
Table_DropChip_Flow Splitter Dimensions.
How does it work?
Droplet Frequency
Droplet Size
applications.png

APPLICATIONS

Droplet Generation for a wide variety of applications:

  • Drop-Seq (Cell / Protein) encapsulation on-chip, see example below.

  • DNA sequencing for target selection / enrichment.

  • Sample / reagent mixing and control of reactions on-chip

  • DNA amplification

  • Biomolecule synthesis

  • Diagnostic chips

  • Drug discovery

For more details on experimental set-ups, visit our Droplet Generation page.

APPLICATION VIDEOS

Cell (or particle) double encapsulation:

The image below illustrates droplets containing cells, enclosed within a shell of oil.  The following is an example of the experimental set-up to achieve double encapsulation.

Droplet Generation_Cell or Particle_doub

Experimental Set-up

  • 3 x ExiGo pumps

  • 3 x Flow Sensors

  • 1 x DropChip (50um x 50um) coated with DropCoat (reagent ensuring hydrophobicity)

  • 1 x DropChip (80um x 80um) uncoated, hydrophilic walls

Table_Cell double encapsulation example.
Applications

RELATED PRODUCTS & ACCESSORIES

Microfluidic Syringe Pumps.jpg

Microfluidic Syringe Pumps

Microfluidic Pressure Pumps.jpg

Microfluidic Pressure Pumps

Flow Sensor_2.jpg

Flow

Sensors

Biochip Inlet Tube.jpg

Tubing &

Connectors

Related Products & Accessories
Demonstration videos

DEMONSTRATIONS & HOW TO...

Training videos
This channel is coming soon!

TRAINING VIDEOS

bottom of page